为什么从串行端口接收数据为空



下面的代码没有错误,与设备的连接似乎也可以工作,尽管我没有从设备获得任何反馈。

在 V.S. 上,我在行myReceivedLines = sp.ReadExisting();放置了一个断点,变量 myReceivedLines 返回 null。

在连接到同一设备的另一个类似程序上,出现了几行反馈(见下文),为什么在我的情况下这个变量为 null?

出现在其他节目中的行:

Connecting...
start
Printer is now online.
echo:Marlin: 1.0.0 RC2
echo: Last Updated: 2012-05-22-1 | Author: eMAKER
...etc...

法典:

 //Fields
    string myReceivedLines;
    //subscriber method for the port.DataReceived Event
    private void DataReceivedHandler(object sender, System.IO.Ports.SerialDataReceivedEventArgs e)
    {
        SerialPort sp = (SerialPort)sender;
        myReceivedLines = sp.ReadExisting();
    }

       protected override void SolveInstance(IGH_DataAccess DA)
      {
        List<string> gcode = new List<string>();
        DA.GetDataList(0, gcode);
        string selectedportname = default(string);
        DA.GetData(1, ref selectedportname);
        int selectedbaudrate = default(int);
        DA.GetData(2, ref selectedbaudrate);
        bool connecttodevice=default(bool);
        DA.GetData(3, ref connecttodevice);
        bool sendtoprint= default(bool);
        DA.GetData(4, ref sendtoprint);
        if (!DA.GetDataList(0, gcode)) return;
        if (!DA.GetData(1, ref selectedportname)) return;
        if (!DA.GetData(2, ref selectedbaudrate)) return;
        if (!DA.GetData(3, ref connecttodevice)) return;
        if (!DA.GetData(4, ref sendtoprint)) return;

        SerialPort port = new SerialPort(selectedportname, selectedbaudrate, Parity.None, 8, StopBits.One); //Create the serial port
        port.DtrEnable = true;   //enables the Data Terminal Ready (DTR) signal during serial communication (Handshaking)
        port.Open();             //Open the port
        port.DataReceived += new SerialDataReceivedEventHandler(DataReceivedHandler);

        if (gcode == null)
        {
            AddRuntimeMessage(GH_RuntimeMessageLevel.Warning, "Specify a valid GCode");
            return;
        }
        if (connecttodevice == true)
        {
            DA.SetDataList(0, myReceivedLines);
        }
        else
        {
            port.Close();
        }
            if (sendtoprint == true)
            {
                foreach (String s in gcode)
                {
                    port.WriteLine(s);
                }
            }
                  }
    if (connecttodevice == true)
    {
        DA.SetDataList(0, myReceivedLines);
    }

SerialPort.ReadExisting() 不能返回 null,最坏的情况是你会得到一个空字符串。 简单的解释是,您在收到任何数据之前正在使用myReceivedLines。 在这种情况下,这很可能是在打开端口后立即使用它的。 在你使用myReceivedLines之前,DataReceived触发的几率正在消失。 代码非常难以理解,您需要对其进行大量修改。 请记住,串行端口将在完全不可预测的时刻接收数据。 您需要让 DataReceived 事件处理程序推送进度。

相关内容

  • 没有找到相关文章

最新更新