格式语句的fortran错误



我正在尝试编译一些fortran代码,但是我对格式语句的错误不断遇到错误。它说我缺少括号和角色,但对我来说看起来不错。我正在用silverfrost编译。该代码如下所示:

!  PROGRAM  TO  SOLVE DEEP-BED DRYING  MODEL
!
!  BASIC  STATEMENTS
!
CHARACTER*20  FiIe1, File2
COMMON  AMo
COMMON  /DENS/  Pmo,  Pme
COMMON  /THICK/ dxo,  Dxe
DIMENSION  AM1(50),  AM2(50),  T(50),  Gs(51),  Vs(51), Ts(51), Dx(50), X(50)
!
!To  define a  number  of  statement  functions
AMe(Ts)=0.62*EXP(-1.116*(Ts-100)**0.3339)
A(Ts, Vs)=(1.2925-0.00058*Ts) * (0.9991-0.0963*Vs)
AK(Ts, Vs)=(0.00273*Ts-0.2609)*(2.0984*Vs+0.2174)
AN(Ts)=0.00222*Ts+0.9599
Ps(Ts)=0.7401-0.001505*Ts
!
!INPUT SECTION OF THE PROGR.A,M
!
PRINT*, 'Input the mass of the sample (g) :'
READ*, Wo
PRINT*, 'Input the initial moisture content (db):'
READ*, AMo
PRINT*, 'lnput the depth of the sample bed (mm):'
READ*, Xo
PRINT*, 'Input the number of layers in the bed:'
READ*, Nx
PRINT*, 'Input the steam temperature at inlet (oC):'
READ*, Tso
PRINT*, 'input the steam flow rate at inlet (kg/(m2.s)):'
READ*, Gso
PRINT*, 'lnput the expected drying time (min):'
READ*, Timeo
PRINT*, 'lnput the time interval- (min) :'
READ*, Dt
!
! TO DEFINE AND OPEN DATA FILES
!
PRINT*, 'Name for the file recording the simulation +process:'
READ*, File1
OPEN (1, FILE=File1)
PRINT*, 'Name for the file recording major data:'
READ*, File2
OPEN (2, FILE=File2)
!
! TO WRITE INPUTTED PARAMETERS IN THE DATA FILES
!
WRITE (1, *) 'Mass of sample:', Wo, ' g'
WRITE (1, *) 'Initial moisture content:', AMo, ' kg/kg'
WRITE (1, *) 'Depth of sample bed:', Xo, 'mm'
WRITE (1, *) 'Number of layers in sample bed:', Nx
WRITE (1, *) 'Steam temperature at inlet', Tso, 'deg C'
WRITE (1, *) 'Steam flow rate at inlet', Gso, 'kg/m2s'
WRITE (1, *) 'Expected drying time', Timeo, ' min'
WRITE (1, *) 'Time interval:', Dt, ' min'
!
WRITE (2, *) 'Mass of sample', Wo, 'g'
WRITE (2, *) 'Initial moisture content', AMo, 'kg/kg'
WRITE (2, *) 'Depth of sample bed', Xo, 'mm'
WRITE (2, *) 'Number of layers in sample bed', Nx
WRITE (2, *) 'Steam temperature at inlet', Tso, ' deg C'
WRITE (2, *) 'Steam flow rate at inlet', Gso, ' kg/m2*s'
WRITE (2, *) 'Expected drying time', Timeo, ' min'
WRITE (2, *) 'Time interval:', Dt, ' min'
!
!BASIC CALCULATION BASED ON THE INPUT DATA
!
Dxo=Xo/1000/Nx
Dxe=0.867*Dxo
D1=0.066
Pmo=4*(Wo/l000)/(3.14159*D1**2*(Xo/1000)*(1+AMo))
Pme=Pmo/0.867
AMeo=AMe(Tso)
NT=NINT(Timeo/Dt)
Pso=Ps(Tso)
Vso=Gso/Pso
!
!TO SET VALUES FOR SOME PHYSTCAL AND THERMODYNAMTC PROPERTIES
!
Cs=2000
Cw1=4193
Cw=4313
C=1245
!
!TO CALCULATE THE INTTIAL MOISTURE CONTENT CONSIDERING STEAM CONDENSATION
!
AMo1=AMo+(C+Cw1*AMo)/(2257000+Cs*(Tso-100))*(100-10)
!
!TO SET JUDGE CRITERION FOR TERMINATING THE DRYING OF A LAYER
!(A small difference between moisture content and equilibrium moisture content)
DM=0.0001
!
!MAJOR DERIVATION FOR DRYING SIMULATION
!
J=0
Time=0
m=1
!
WRITE(2, 100)
100 FORMAT(4H  J, 9H  T(min), 8H  M(db),7H  Gs , 10H  Ts(C) ,9H Front1, 5H  L1, 9H  Front2, 5h L2, 9H  Depth)
!
200 m5=m-1
    IF (J .GT. Nt) GO to 800
!
    PRINT*, ' ' 
    PRINT*, ' ' 
    PRINT*, 'Time inverval:', J, '   Drying time:', Time, ' min'
    WRITE(1, x) ' ' 
    WRITE(1, *) 'Time interval:', J, '   Drying time:', Time, ' min'
    WRITE(*, 300)
    WRITE(1, 300)
300 FORMAT(1x, 3H, I, 7H, X(i), 8H  M(i), 10H   T(i), 10H   Gs(i), 8H   Ts(i))
!
    AveM=0
!
!   For dried region
!
    IF(m .GT. 1) THEN
        DO 500 i=1, m-1
            Dx(i)=Dxe
            X(i)=(i-0.5)*Dxe
            AM1(i)=AM2(i)
            T(i)=Tso
            Gs(i)=Gso
            Vs(i)=Vso
            Ts(i)=Tso
            AveM=AveM+AM1(i)
            WRITE(*, 400) i, X(i), AM1(i), T(i), Gs(i), Ts(i)
            WRITE(1, 400) i, X(i), AM1(i), T(i), Gs(i), Ts(i)
400         FORMAT(1X, I3, 2X, F6.4, 2X, F6.4, 2X, F8.3, 2X, F7.3, 2X, F7.3)
500     CONTINUE
    ENDIF
!   Calculation of the drying front position
    IF (m .EQ. l) THEN
            X1=-1
            No1=-1
        ELSE
            Xl=X(m-1)+Dx(m-1)/2
            No1=m-1
    ENDIF
!
    IF (m .GT. Nx) GO TO 900
!
    Ts(m)=Tso
    Vs(m)=Vso
    L=0
    DO 600 i=m, Nx
        IF(L .NE.0) GO TO 510
!
!   For drying region
!
    If (J .EQ. O) THEN
        Am1(i)=AMo1
       Else
         AM1(i)=AM2(i)
       ENDIF
      Dx(i)=Dxx(AM1(i))
      IF (i .EQ. 1) THEN
        X(i)=Dx(i)/2
        ELSE
          X(i)=X(i-1)+Dx(i-1)/2+Dx(i)/2
        ENDIF
!
!   To define transition variables
!
    AMe5=AMe(Ts(i))
    A5=A(Ts(i),Vs(i))
    AK5=AK(Ts(i),Vs(i))
    AN5=AN(Ts(i))
    Ps5=Ps(Ts(i))
    P5=P(AMl(i))
    Dt5=Dt* 60
    !
    !   Derivation
    !
    AMmax=A5*(AMo-AMe5)/EXP((AN5-1)/AN5)+AMe5
        IF (AM1(i) .GE. AMmax) THEN
            AM2(i)=AM1(i)-Dt5*AK5*AN5*(AMmax-AMe5)*(ALOG(A5*(AMo-AMe5)/(AMmax-AMe5))/AK5)**((AN5-1)/AN5)/60
    ELSE
            AM2(i)=AM1(i)-Dt5*AK5*AN5*(AM1(i)-AMe5)*(ALOG(A5*(AMo-AMe5)/(AM1(i)-AMe5))/AK5)**((AN5-1)/AN5)/60
    ENDIF
DR=(AM2(i)-AM1(i))/Dt5
!
        IF (AM1(i) .GE. AMo) THEN
            T(i)=100
            DerT=0
            ELSE
                T(i)=Tso-(Tso-100)*(AM1(i)-AMeo)/(AMo-AMeo)
                DerT=-(Tso-l00)/(AMo-AMeo)*DR
            ENDIF
!
Gs(i)=Vs(i)*Ps5
Gs(i+l)=Gs(i)-Dx(i)*P5*DR
Vs(i+1)=Gs(i+1)/Ps5
Hv5=Hv(AMl(i), T(i))
Ts(i+1)=Ts(i)+Dx(i)*P5*(Hv5+Cs*(Ts(i)-T(i)))/(Gs(i)*Cs)*DR-Dx(i)*P5*(C+Cw*AMl(i))/(Gs(i)*Cs)*DerT
!
!   To find the first layer in wet region
!
    IF (Ts(i+l) .LE. l00) THEN
        Ts(i+1)=100
        L=i
    ENDIF
!
!   To check if the layer has been dried to equilibrium
!
        IF ((AM2(i)-AMeo) .LE. DM) THEN
            m5=i
            AM2(i)=AMeo
            ENDIF
        GO TO 520
!
!   For wet region
!
510     AM1(i)=AMo1
        AM2(i)=AMo1
        T(i)=100
        Gs(i+l)=Gs(i)
        Vs(i+1)=Vs(i)
        Ts(i+1)=100
!
        Dx(i)=Dxx(AM1(i)) 
        IF (i .EQ. 1) THEN
            X(i)=Dx(i)/2
            ELSE
                X(i)=X(i-1)+Dx(i-1)/2+Dx(i)/2
            ENDIF
!
520     AveM=AveM+AM1(i)
        WRITE(*, 400) i, X(i), AM1(i), T(i), Gs(i), Ts(i)
        WRITE(1, 400) i, X(i), AM1(i), T(i), Gs(i), Ts(i)
600 CONTINUE
!
!   Calculation of wet front position
        IF (L .EQ. O) THEN
            X2=-1
            No2=-1
           ELSE
             X2=X(L)+Dx(L)/2
             No2=L+1
             ENDIF
!
      AveM=AveM/Nx
      Depth=X(Nx)+Dx(Nx)/2
!
    WRITE(*, 100)
    WRITE(*, 700) J, Time, AveM, Gs(Nx*1), Ts(Nx*1), XI, No1, X2, No2, Depth
    WRITE (2, 700) J, Time, AveM, Gs(Nx+1), Ts(Nx*1), X1, No1, X2, No2, Depth
700 FORMAT(I4, 2X, F7.3, 2X, F6.4, 2X, F6.4, 2X, F7.3, 2X, F7.4, 2x, I3, 2X, F7.4, 2X, I3, 2x, F7.4)
!
    J=J+1
    Time=Time+Dt
    m=m5+1
    GO TO 200
!
800 PRINT*, ' '
    PRINT*, 'The drying time was up to the specified time.'
    PRINT*, 'The drying simulation was stopped.'
    PRINT*, 'The sample was not dried to equilibrium'
    WRITE(1,*)  ' '
    WRITE(1,*) 'The drying time was up to the specified time.'
    WRITE(1,*) 'The drying simulation was stopped'
    WRITE(1,*) 'The sample was not dried to equilibrium'
    WRITE(1,*) ' '
    WRITE(2,*) 'The drying time was up to the specified time'
    WRITE(2,*) 'The drying simulation was stopped'
    WRITE(2,*) 'The drying simulation was stopped'
    WRITE(2,*) 'The sample was not dried to equilirbium'
    GO TO 910
!
900 No2=-1
    X2=-1
    AveM=AveM/Nx
    WRITE(*, 100)
    WRITE(*, 700) J, Time, AveM, Gs(Nx+1), Ts(Nx+1), X1, No1, X2, No2, Depth
    WRITE(2, 700) J, Time, AveM, Gs(Nx+1), Ts(Nx+1), X1, No1, X2, No2, Depth
!
    PRINT*, ' '
    PRINT*, 'The sample was dried to equilibrium'
    PRINT*, 'The drying simulation was stopped.'
    WRITE(1,*)  ' '
    WRITE(1,*) 'The sample was dried to equilibrium'
    WRITE(1,*) 'The drying simulation was stopped'
    WRITE(2,*) ' '
    WRITE(2,*) 'The sample was not dried to equilirbium'
    WRITE(2,*) 'The drying simulation was stopped'
!
910 CLOSE(1)
    CLOSE(2)
END
!
!**********************************************************************************
!
!   EXTERNAL FUNCTION FOR LATENT HEAT OF EVAPORATION
!
        FUNCTION Hv(AM, T)
        Hfg=2257000-2916.7*(T-100)
        IF (AM .GE. 0.2) THEN
                Hv=Hfg
            ELSE
                Hv=Hfg*(1+EXP(-19.9*AM))
        ENDIF
        RETURN
        END
!
!   EXTERNAL FUNCTION FOR BULK DENSITY
!
        FUNCTION P(AM)
        COMMON AMo/DENS/ Pmo, Pme
        IF (AM .GE. AMo) THEN
            P=Pmo
            ELSE IF (AM .LT. 0.11) THEN
                P=Pme
            ELSE
                P=Pmo-(Pmo-Pme)*(AMo-AM)/(AMo-0.11)
            ENDIF
        RETURN
        END
!
!   EXTERNAL FUNCTION FOR LAYER THICKNESS
!
        FUNCTION Dxx(AM)
        COMMON AMo/THICK/ Dxo, Dxe
        IF (AM .GE. AMO) THEN
            Dxx=Dxo
            ELSE IF (AM .LT. 0.11) THEN
                Dxx=Dxe
            ELSE
                Dxx=Dxo-(Dxo-Dxe)*(AMo-AM)/(AMo-0.11)
            ENDIF
        RETURN
        END
!
!****************************************************************************************

和错误如下:

Compiling and linking file: SHSDRYING.F95
C:UsersstevaDesktopSHSDRYING.F95(104) : error 58 - Unpaired right bracket(s)
C:UsersstevaDesktopSHSDRYING.F95(45) : error 259 - Scalar, default-kind, CHARACTER expression expected for the FILE keyword
C:UsersstevaDesktopSHSDRYING.F95(45) : warning 868 - Opening unit 1 may affect the operation of input from the default unit '*' - are you sure you want to do this?
C:UsersstevaDesktopSHSDRYING.F95(48) : warning 868 - Opening unit 2 may affect the operation of output to the default unit '*' - are you sure you want to do this?
C:UsersstevaDesktopSHSDRYING.F95(116) : warning 792 - Comma missing in format
C:UsersstevaDesktopSHSDRYING.F95(116) : warning 792 - Comma missing in format
C:UsersstevaDesktopSHSDRYING.F95(116) : error 270 - Missing width count for 'G' descriptor
C:UsersstevaDesktopSHSDRYING.F95(116) : warning 792 - Comma missing in format
C:UsersstevaDesktopSHSDRYING.F95(116) : error 274 - Unknown edit descriptor '(', or missing comma
C:UsersstevaDesktopSHSDRYING.F95(292) : warning 868 - Closing unit 1 may affect the operation of input from the default unit '*' - are you sure you want to do this?
C:UsersstevaDesktopSHSDRYING.F95(293) : warning 868 - Closing unit 2 may affect the operation of output to the default unit '*' - are you sure you want to do this?
C:UsersstevaDesktopSHSDRYING.F95(103) : error 90 - FORMAT label 100 does not exist
Compilation failed.

单位5,6和1,2(和其他单元)保留...如果您使单位= 1变为单位= 21,并且单位= 2变为单位= 22,则将起作用。

更好的是使用newunit

!  PROGRAM  TO  SOLVE DEEP-BED DRYING  MODEL
!
!  BASIC  STATEMENTS
!
PROGRAM DEEP_BED_DRYING               !New
IMPLICIT NONE                         !New
CHARACTER*20  FiIe1, File2
COMMON  AMo
COMMON  /DENS/  Pmo,  Pme
COMMON  /THICK/ dxo,  Dxe
...
OPEN (NEWUNIT=MyUnit1, FILE=File1)    !New
WRITE(*,*)' Unit1=',MyUnit1           !New
...
OPEN (NEWUNIT=MyUnit2, FILE=File2)    !New
WRITE(*,*)' Unit2=',MyUnit2           !New
enter code here
!WRITE(1,*) ...
WRITE(MyUnit1,*) ...

隐式无是一种使用的坏习惯。我会排成一行,以便于阅读...

WRITE (1, *) 'Mass of sample:'                 , Wo    , ' g'
WRITE (1, *) 'Initial moisture content:'       , AMo   , ' kg/kg'
WRITE (1, *) 'Depth of sample bed:'            , Xo    , 'mm'
WRITE (1, *) 'Number of layers in sample bed:' , Nx 
WRITE (1, *) 'Steam temperature at inlet'      , Tso   , 'deg C'
WRITE (1, *) 'Steam flow rate at inlet'        , Gso   , 'kg/m2s'
WRITE (1, *) 'Expected drying time'            , Timeo , ' min'
WRITE (1, *) 'Time interval:'                  , Dt    , ' min'

您要么需要与-132进行编译,要么使用线路延续...

.f77或-fixed编译器开关(任何n列#6):

      WRITE(2, 100)
100   FORMAT(4H  J, 9H  T(min), 8H  M(db),7H  Gs , 10H  Ts(C) ,
!234567
     &       9H Front1, 5H  L1, 9H  Front2, 5h L2, 9H  Depth)

.f90或-free编译器开关(&在最后):

WRITE(2, 100)                                                 !Here
100 FORMAT(4H  J, 9H  T(min), 8H  M(db),7H  Gs , 10H  Ts(C) ,  &
!234567
           9H Front1, 5H  L1, 9H  Front2, 5h L2, 9H  Depth)

程序中的格式语句使用hollerith编辑描述符,这是从语言中删除的fortran 95的功能。

hollerith编辑描述符是 n hxxx的形式 - 其中 H之后的 n 字符等于字符文字。已确定的语句的问题(至少)是,旨在关闭格式语句的括号被视为文字的一部分 - 可能是因为从源中删除了空间或类似。

100 FORMAT(...9H  Depth)
                123456789

错误消息还确定了名为 File1的变量不适合开放语句中的file = specifier。这是因为File1没有可变声明,因此被认为是真实的类型。有变量FiIe1的声明。IMPLICIT NONE有助于找到这些类型的拼写错误,但是该代码显然是使用隐式键入编写的。

这些错误表明源来自光学特征识别或类似。如果是这样,您将需要非常注意源中其他地方的OCR错误。