我正在尝试使用虚拟序列端口程序发送数据并通过串行通信接收。但这是问题...让我们假设A是传输数据,并且B是接收数据。
将数据发送到B。B接收数据两次(SerialPort_DataReceived事件发生两次!)。
每次b关闭序列上并再次打开时,序列port_datareceived事件发生增加。
我不知道为什么会发生。
A(transmit)
BaudRate = 9600
Parity = None
DataBits = 8
StopBits = 1
public transmit()
{
InitializeComponent();
foreach (String s in System.IO.Ports.SerialPort.GetPortNames())
{
cBoxPort.Items.Add(s);
}
}
private void CBoxBaudRate_SelectedIndexChanged(object sender, EventArgs e)
{
serialPort1.BaudRate = Convert.ToInt32(cBoxBaudRate.Text);
}
private void CBoxStopBits_SelectedIndexChanged(object sender, EventArgs e)
{
serialPort1.StopBits = (StopBits)Enum.Parse(typeof(StopBits), cBoxStopBit.Text);
}
private void CBoxDataBits_SelectedIndexChanged(object sender, EventArgs e)
{
serialPort1.DataBits = Convert.ToInt32(cBoxDataBits.Text);
}
private void CBoxParityBits_SelectedIndexChanged(object sender, EventArgs e)
{
serialPort1.Parity = (Parity)Enum.Parse(typeof(Parity), cBoxParity.Text);
}
private void btnConnect_Click(object sender, EventArgs e)
{
try
{
serialPort1.PortName = cBoxPort.Text;
serialPort1.BaudRate = Convert.ToInt32(cBoxBaudRate.Text);
serialPort1.DataBits = Convert.ToInt32(cBoxDataBits.Text);
serialPort1.StopBits = (StopBits)Enum.Parse(typeof(StopBits), cBoxStopBit.Text);
serialPort1.Parity = (Parity)Enum.Parse(typeof(Parity), cBoxParity.Text);
serialPort1.DataReceived += new SerialDataReceivedEventHandler(serialPort1_DataReceived);
serialPort1.Open();
txtReceive.AppendText("Connectedn");
btnConnect.Enabled = false;
btnClose.Enabled = true;
btnSend.Enabled = true;
}
catch (Exception ex)
{
return;
}
}
private void btnClose_Click(object sender, EventArgs e)
{
if (serialPort1.IsOpen)
{
serialPort1.Close();
btnClose.Enabled = false;
btnConnect.Enabled = true;
btnSend.Enabled = false;
txtReceive.AppendText("Disconnectedn");
}
}
private void btnSend_Click(object sender, EventArgs e)
{
byte[] bytesend = { 0x00 };
Debug.WriteLine("111");
serialPort1.Write(bytesend, 0, bytesend.Length);
}
private void serialPort1_DataReceived(object sender, SerialDataReceivedEventArgs e)
{
Debug.WriteLine("444");
}
}
b(接收)
byte[] bytesend;
//Initial Conditions(SerialPort)
private void receive_Load(object sender, EventArgs e)
{
cBoxBaudRate.SelectedIndex = 0; //BaudRate = 9600
cBoxParity.SelectedIndex = 0; //Parity = None
cBoxDataBits.SelectedIndex = 0; //DataBits = 8
cBoxStopBit.SelectedIndex = 0; //StopBits = 1
cBoxPort.SelectedIndex = 1;
btnConnect.Enabled = true;
btnClose.Enabled = false;
}
//Show usable CommPort
public receive()
{
InitializeComponent();
foreach (String s in System.IO.Ports.SerialPort.GetPortNames())
{
cBoxPort.Items.Add(s);
}
}
//Connection
private void btnConnect_Click(object sender, EventArgs e)
{
serialPort1.PortName = cBoxPort.Text;
serialPort1.BaudRate = Convert.ToInt32(cBoxBaudRate.Text);
serialPort1.DataBits = Convert.ToInt32(cBoxDataBits.Text);
serialPort1.StopBits = (StopBits)Enum.Parse(typeof(StopBits), cBoxStopBit.Text);
serialPort1.Parity = (Parity)Enum.Parse(typeof(Parity), cBoxParity.Text);
serialPort1.DataReceived += new SerialDataReceivedEventHandler(serialPort1_DataReceived);
serialPort1.Open();
btnConnect.Enabled = false;
btnClose.Enabled = true;
}
private void btnClose_Click(object sender, EventArgs e)
{
if (serialPort1.IsOpen)
{
serialPort1.Close();
btnClose.Enabled = false;
btnConnect.Enabled = true;
}
}
private void serialPort1_DataReceived(object sender, SerialDataReceivedEventArgs e)
{
Debug.WriteLine("222");
}
当我调试此代码输出时,代表111222222。并且当我按关闭和连接按钮时,输出表示111 222 222 222。
每次B关闭序列上并再次打开时, SerialPort_DataReceived事件发生增加。
对,因为就像我说的那样,您应该只接线一次DataReceived事件。每次单击按钮时,都会添加另一个处理程序,从而导致单个接收的多个触发。这与多线程无关。将从按钮单击事件从按钮上移动处理程序的线路到加载事件:
:private void transmit_Load(object sender, EventArgs e)
{
serialPort1.DataReceived += new SerialDataReceivedEventHandler(serialPort1_DataReceived); // now it only gets called once
// ... other existing code ...
}
private void btnConnect_Click(object sender, EventArgs e)
{
try
{
serialPort1.PortName = cBoxPort.Text;
serialPort1.BaudRate = Convert.ToInt32(cBoxBaudRate.Text);
serialPort1.DataBits = Convert.ToInt32(cBoxDataBits.Text);
serialPort1.StopBits = (StopBits)Enum.Parse(typeof(StopBits), cBoxStopBit.Text);
serialPort1.Parity = (Parity)Enum.Parse(typeof(Parity), cBoxParity.Text);
// serialPort1.DataReceived += new SerialDataReceivedEventHandler(serialPort1_DataReceived); // remove this line
serialPort1.Open();
txtReceive.AppendText("Connectedn");
btnConnect.Enabled = false;
btnClose.Enabled = true;
btnSend.Enabled = true;
}
catch (Exception ex)
{
return;
}
}
您还需要在接收表格中做同样的事情。