ServiceClient (Microsoft.Azure.Devices) OpenAsync Issue



运行 Azure 辅助角色(事件处理器主机)一段时间后,我们收到此奇怪错误。最初我认为这是由于我们通过ServiceClient(Microsoft.Azure.Devices)排队太多云到设备的消息,但肯定会看到"设备队列深度不能超过50条消息"错误。我们在关闭和处置方面也非常谨慎。

代码如下:

public async Task<AzureDevices.Message> SendCloudToDeviceAsync(string deviceId, string message, bool ack = false, string MessageId = null)
{
AzureDevices.ServiceClient ServiceClient = null;
try
{                
ServiceClient = AzureDevices.ServiceClient.CreateFromConnectionString(Configuration.IOTHubConnectionString);
await ServiceClient.OpenAsync();
logger.Info(string.Format("Encoding & Sending message {0} for Device {1}", message, deviceId));
var commandMessage = new AzureDevices.Message(Encoding.ASCII.GetBytes(message))
{
//Whether we require feedback from the hub...
Ack = ack == true ? AzureDevices.DeliveryAcknowledgement.Full : AzureDevices.DeliveryAcknowledgement.None,
MessageId = MessageId == null ? Guid.NewGuid().ToString() : MessageId,
//ExpiryTimeUtc = expiry,
To = deviceId
};
await ServiceClient.SendAsync(deviceId, commandMessage);
Common.ExtensionMethods.WriteHighlightedMessage(string.Format("Sent message {0} with MessageId {1}", message, commandMessage.MessageId), ConsoleColor.Green);
logger.Info(string.Format("Sent message {0} with MessageId {1}", message, commandMessage.MessageId));
return commandMessage;
}
catch (Exception e)
{
Common.ExtensionMethods.WriteHighlightedMessage(string.Format("SendCloudToDeviceMessageAsync: {0}", e.Message), ConsoleColor.Red);
if (e.Message.Contains("Device Queue depth cannot exceed 50 messages"))
{
logger.Warn("SendCloudToDeviceMessageAsync for device {0}: {1}", deviceId, e.Message);
if (e.InnerException != null) logger.Warn(e.InnerException);
}
else
{
logger.Error("SendCloudToDeviceMessageAsync for device {0}: {1}", deviceId, e.Message);
logger.Error(e.StackTrace);
if (e.InnerException != null) logger.Error(e.InnerException);
}
}
finally
{
if(ServiceClient != null)
{
await ServiceClient.CloseAsync();
ServiceClient.Dispose();
}
}
return new AzureDevices.Message();
}

以下是 InnerException:System.IO.IOException 的一部分:加密操作失败,请参阅内部异常。 ---> System.ComponentModel.Win32Exception:上下文已过期,无法再使用

触发错误的确切行位于 OpenAsync() 上。 我很可能在多个线程上执行此操作,有限制吗?

在未来的版本中,我们不会做一个"应用层ACK",而是让决策者认为服务器通过MQTT ACK是满意的。这将减少我们发送的云到设备消息的数量。

设备到云命令在 IoT 中心排队,仅在连接设备时异步传递。每个设备只能排队 50 个命令。请看这里。即使已关闭服务客户端,该命令仍位于服务端的队列中,直到设备客户端完全收到消息。所以我认为你应该确保队列中的命令没有超过限制。